Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add filters








Year range
1.
Braz. oral res ; 25(3): 274-279, May-June 2011. ilus, tab
Article in English | LILACS | ID: lil-590047

ABSTRACT

The purpose of this study was to test the hypothesis that both human and bovine sclerotic dentin have similar hardness properties, in addition to similar micromorphological characteristics. Sixteen teeth (8 human and 8 bovine) exhibiting exposed dentin in the incisal edge and showing characteristics typical of sclerosis were used. Vickers surface microhardness testing was conducted. Three areas of the dentin surface of each specimen were selected. All teeth were processed for scanning electron microscopy in order to estimate the amount (in percentage) of solid dentin on the sclerotic dentin surface. The data were compared by Student's t test (α = 0.05). The micromorphological and microhardness data were compared by Pearson's linear correlation test (α = 0.05). The mean percentages of solid dentin of human and bovine sclerotic dentin were similar (human 90.71 ± 0.83 and bovine 89.08 ± 0.81, p = 0.18). The mean microhardness value (VHN) of human sclerotic dentin was significantly higher than that of bovine sclerotic dentin (human 45.26 ± 2.92 and bovine 29.93 ± 3.83, p = 0.006). No correlation was found between the microhardness values and the amount of solid dentin in the sclerotic dentin, irrespective of the species considered (human R² = 0.0240, p = 0.714; bovine R² = 0.0017, p = 0.923; and combined R² = 0.038, p = 0.46). We concluded that although both bovine and human sclerotic dentin present a similar amount of solid tissue, human sclerotic dentin presents higher microhardness than bovine sclerotic dentin.


Subject(s)
Animals , Cattle , Humans , Dentin/pathology , Dentin/ultrastructure , Hardness Tests , Microscopy, Electron, Scanning , Sclerosis , Surface Properties
2.
RSBO (Impr.) ; 6(2): 123-128, jun. 2009. tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-514879

ABSTRACT

Introdução: A literatura mostra características diferentes entre a dentina normal e a esclerosada. A dureza é uma das propriedades bastante utilizadas para comparar tanto os materiais restauradores como os tecidos biológicos. Objetivo: Comparar as características clínicas de dureza entre a dentina bovina normal e a esclerosada, por meio do teste de microdureza. Material e métodos: Foram utilizados 20 dentes bovinos divididos em dois grupos: GI (íntegros) e GII (com características de esclerose). Os dentes foram incluídos em resina acrílica com os bordos incisais expostos e paralelos ao plano oclusal. Os espécimes receberam acabamento e polimento e ficaram armazenados em água destilada em temperatura ambiente por 7 dias. Para o teste de microdureza foi utilizado o endentador Vickers com carga de 50 gf durante 45 s. Selecionaram-se três áreas para cada espécime, e em cada área foram realizadas cinco endentações, totalizando 15 leituras por espécime. Resultados: Os dados foram registrados e submetidos à análise estatística pelo teste t (Student), com nível de significância de 5%. Os resultados mostraram não haver diferenças estatisticamente significantes entre as médias de microdureza dos dois grupos estudados (GI: 36,82±9,45; GII: 32,4±12,2) (p = 0,383). Conclusão: A dentina bovina normal mostrou valores de microdureza Vickers semelhantes aos da dentina bovina esclerosada.


Introduction: The literature shows different characteristics between normal and sclerotic dentin. Hardness is a property that has been very used to compare restorative materials and biological tissues. Objective: The aim of this study was to compare the hardness clinical characteristics between the normal and the sclerotic bovine dentin, through the microhardness test. Material and methods: 20 bovine teeth were divided in two groups: GI (normal) and GII (with characteristics of sclerosis). The teeth were mounted in acrylic resin cylinders with exposure of dentin along the incisal edges. The specimens received finishing and polishing following by storage in distilled water at ambient temperature for 7 days. Microhardness measurements were made using a Vickers indenter microhardness tester under a load of 50 gf for 45 s. In this study 3 areas per specimen were selected and each area received 5 indentations, resulting in 15 indentations per specimen. Results: The data were statistically processed using the Student's t-test. The level of significance was 5%. The results showed no significant differences between the mean values of the two groups (GI: 36.82±9.45; GII:32.4±12.2) (p = 0.383). Conclusion: The normal bovine dentin presented similar microhardness Vickers values to the sclerotic bovine dentin.

3.
Rev. odonto ciênc ; 22(58): 359-363, out.-dez. 2007. ilus
Article in Portuguese | LILACS | ID: lil-487218

ABSTRACT

Um importante fator no estudo da oclusão diz respeito à correta detecção da presença de contatos oclusais no lado de balanceio, sua intensidade e localização. O presente estudo teve por objetivo avaliar a ocorrência de contatos em balanceio em 30 indivíduos jovens, durante o ato mastigatório, utilizando como material de registro uma mistura de verniz cavitário e pó de fosfato de zinco. Vinte e três jovens ou 76.67% dos participantes apresentaram contatos no lado de balanceio bilateralmente, normais ou interferentes. Considerando-se apenas os contatos considerados normais, que não excederam a intensidade dos contatos no lado de trabalho, 50% dos participantes apresentaram contatos bilaterais, 6.67% apresentaram contatos unilaterais no lado direito e 20% apresentaram contatos unilaterais no lado esquerdo. A metodologia funcional empregada na detecção de contatos em balanceio evidenciou sua presença de maneira clara e precisa, comparativamente ao método que emprega papel carbono articular. Os resultados obtidos permitiram concluir que contatos oclusais no lado de balanceio em indivíduos jovens são um achado funcional freqüente.


An important factor in occlusion study is related to the correct balancing-side contacts detection, its intensity and location. This study intended to evaluate balancing-side contacts occurrence in 30 young people, during mastication, using a mixture of varnish and zinc cement powder. Twenty-three young people or 76.67% of the participants showed bilateral balancingside contacts, normal or interferent. Considering only the normal contacts, it means, the ones which did not exceed working-side contacts intensity, 50% of the participants showed bilateral contacts, 6.67% showed unilateral contacts on the right side and 20% showed unilateral contacts on the left side. The functional methodology used in balancing-side contact detection denoted its presence clearly and accurately, comparatively to the carbon paper method. The results allowed us to conclude that balancing-side contacts in young people are a frequent finding.


Subject(s)
Humans , Adult , Mastication , Dental Occlusion, Balanced
4.
J. Health Sci. Inst ; 25(3): 313-318, jul.-set. 2007.
Article in Portuguese | LILACS, BBO | ID: biblio-873773

ABSTRACT

O teste de microtração é uma importante ferramenta para o estudo da resistência adesiva, introduzida por Sano et al.24, em 1994. A nova proposta parecia solucionar as limitações dos ensaios tradicionais de cisalhamento e tração, tais como fraturas predominantemente coesivas nos substratos testados, além de permitir a localização das áreas de adesão e uma diminuição na dimensão dos espécimes. Entretanto, a confecção dos corpos-de-prova para execução do teste mostrou-se crítica, e suas particularidades se refletem nos resultados de resistência adesiva obtidos. Uma série de fatores devem ser considerados na análise dos resultados; o substrato envolvido, formato do corpo-de-prova, método de corte para sua obtenção, área de adesão e características das superfícies fraturadas são alguns dos itens que merecem ser analisados. Existem uma variedade de protocolos para execução do teste, o que dificulta a comparação entre os resultados obtidos. Cabe, portanto,realizar uma discussão crítica sobre os relatos encontrados na literatura


Subject(s)
Dental Bonding , Dental Leakage , Tensile Strength , Root Canal Filling Materials , Shear Strength
5.
Odonto (Säo Bernardo do Campo) ; 15(29): 73-80, jan.-jun. 2007. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-518386

ABSTRACT

O objetivo desta pesquisa foi comparar a adaptacao marginal entre restauracoes de ceramica feldspatica (Noritake) e duas resinas compostas de laboratorio (Artglass e Targis). Analisou-se, atraves da microscopia optica, a magnitude da fenda marginal nas faces mesial, distal e lingual. Um pre-molar superior foi preparado para receber uma restauracao do tipo onlay MOD com cobertura da cuspide lingual. A partir deste elemento, foram confeccionadas 30 replicas em NiCr divididas em 3 grupos: l) Noritake; ll) Artglass; lll) Targis. As restauracoes foram posicionadas em suas respectivas replicas e observadas ao microscopio optico (40X), conectado a um microcomputador. As imagens foram capturadas atraves do software Microsoft VidCap 32 e as fendas medidas com auxilio de um cursor de distancia (software Imagelab 2000). As medias (â sm) obtidas foram: grupo l) mesial 64,50 (+38,26), lingual 47,50 (+35,69) e distal 53,00 (+29,36); grupo ll) mesial 56,00 (+25,03), lingual 35,50 (+25,65) e distal 56,00 (+19,55); grupo lll) mesial 69,50 (+9,56), lingual 53,00 (+20,44) e distal 55,50 (+29,29). A analise de variancia de dois fatores (face e material) demonstrou que nao houve diferencas significantes entre os materiais estudados (5%). Entretanto, foram encontradas diferencas significantes entre as faces e foi, entao, aplicado o teste de Tukey (5%). As medias (µm) encontradas foram: mesial 63,33, distal 54,33 e lingual 45,33. Conclusoes: nao houve diferenca significante entre a adaptacao marginal dos materiais estudados (Noritake, Artglass e Targis). A face mesial presentou maior fenda, quando comparada a lingual.


The objective of this research was to compare the marginal adaptation between feldspatic ceramic (Noritake) and two laboratory composite resins (Artglass and Targis). The magnitude of the marginal fissure in the mesial, distal and lingual faces was analyzed through optical microscopy. An upper pre-molar was prepared to receive an onlay restoration covering lingual cuspid. Starting from this element, 30 replicas were made in NiCr, and divided into 3 groups: l) Noritake; ll) Artglass; lll) Targis. Restorations were positioned in their respective replicas and observed through optical microscope (40X) connected to a microcomputer. The images were captured by a Microsoft VidCap 32 software and the fissures measured with the aid of a distance cursor (Imagelab 2000 software). The averages (ìm) obtained were: group l) mesial 64,50 (+38.26), lingual 47.50 (+35.69) and distal 53.00 (+29.36); group ll) mesial 56.00 (+25.03), lingual 35.50 (+25.65) and distal 56.00 (+19.55); group lll) mesial 69.50 (+9.56), lingual 53.00 (+20.44) and distal 55.50 (+29.29). The results, through the Two-factor Analysis of Variance (face and material), demonstrated that there were no significant differences among the studied materials. However, significant differences were found among the faces, then, it was applied the TukeyÆs test (5%). The averages (µm) found were: mesial 63.33, distal 54.33 and lingual 45.33. Conclusions: there was no significant difference among the marginal adaptation of the studied materials (Noritake, Artglass and Targis). Mesial faces presented larger fissures when compared to the lingual faces.


Subject(s)
Ceramics , Composite Resins , Dental Marginal Adaptation , Dental Materials , Inlays
6.
São Paulo; s.n; 2007. 100 p. ilus, tab, graf, ^eCD. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-494640

ABSTRACT

A prática clínica evidencia a necessidade de qualidade na adesão a tecidosdentinários alterados, a exemplo da dentina esclerosada, comumenteencontrada em pacientes idosos. Estudos in vitro e in vivo demonstram umaresistência adesiva à dentina esclerosada menor comparativamente ànormal. A dentina bovina vem sendo utilizada em substituição à dentinahumana em testes de adesão; entretanto, não há relatos na literatura dautilização de substrato bovino com características de esclerose. Os objetivosdeste estudo foram comparar a morfologia superficial da dentina esclerosadabovina e humana, e avaliar a influência de diferentes tratamentos dentináriosna adesão de um sistema etch and rinse à dentina esclerosada bovina. Paraa análise morfológica, foram utilizados incisivos bovinos (n=3) e humanos(n=3) com desgaste incisal e exposição de dentina com características deesclerose: acastanhada, lisa e brilhante - o aspecto vítreo. Os dentes forampreparados para avaliação através de microscopia eletrônica de varredura(MEV). Três áreas pré-estabelecidas de cada espécime forameletromicrografadas. Os números de túbulos abertos por área foram obtidosnas eletromicrografias (n=9 por espécime) para efeito de comparação. Osresultados não revelaram diferenças estatísticamente significantes (p<0,05)entre o número de túbulos nos dois substratos comparados.


Clinical practice evidences the need for quality in bonding to altered dentintissues, as is the case of sclerotic dentin, commonly found in aged patients.In vitro and in vivo studies demonstrate lower bond strength to scleroticdentin as compared to normal dentin. Bovine dentin has been used toreplace human dentin in bond strength tests. However, there are no reportsin the literature on the use of bovine substrate with characteristics ofsclerosis. The objectives of this study were to compare the superficialmorphology of bovine and human sclerotic dentin, and to assess theinfluence of different dentin treatments on the bonding of an etch and rinsesystem to bovine sclerotic dentin. For the morphological analysis we usedbovine (n=3) and human (n=3) incisors, with exposure of dentin withcharacteristics of sclerosis: brownish, smooth and shiny – the vitreousappearance. The teeth were prepared for assessment on a scanning electronmicroscope (SEM). Three pre-determined areas of each sample weresubmitted to the SEM. The number of open tubule per area was obtained inthe electron micrographs (n=9 per sample) for comparison purposes. Theresults did not show statistically significant differences (p<0.05) between thenumber of tubule in the two substrates compared (Human dentin 31.89 ±23.94; Bovine dentin 30.33 ± 18.14). To assess the bond strength we used.


Subject(s)
Humans , Animals , Dentin/pathology , Dentin/ultrastructure , Cattle , Dental Bonding , Microscopy, Electron, Scanning , Sclerosis
8.
Rev. Assoc. Paul. Cir. Dent ; 60(6): 485-488, nov.-dez. 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-543801

ABSTRACT

A Síndrome do dente gretado (SDG) é uma entidade caracterizada pela presença de trinca ou fratura incompleta de esmalte ou esmalte e dentina, em elemento dental comumente restaurado. A difícil visualização da trinca e o relato de sintomas nem sempre elucidativo do paciente, tornam seu diagnóstico por vezes complexo. O tratamento imediato com o objetivo de conter a propagação da fratura é absolutamente necessário e usualmente culmina com a remissão dos sintomas. O tratamento presume ajuste oclusal adequado e um "abraçamento" dental, seja por meio de restaurações metálicas fundidas com recobrimento de cúspides, seja por meio de restaurações diretas ou indiretas associadas a técnicas adesivas.


The cracked-tooth syndrome (CTS) is a clinical occurrence characterized by presence of crack or uncompleted enamel and dentin fracture in irequently restored teeth. The crack difficult visualization and the patient obscure symptoms reports becomes complex the diagnostico. The immediate treatment aiming to contain the crack propagation is absolutely necessary and usually results in symptoms reduction. The indicated treatment is occlusal adequate adjustment and a dental "reinforce" by indirect cast alloy onlays with cupids covering. Additionally direct and indirect restorations associated with adhesive techniques could be used.


Subject(s)
Humans , Dental Restoration, Permanent , Tooth Fractures/diagnosis , Tooth Fractures/rehabilitation
9.
J. Health Sci. Inst ; 24(2): 137-140, abr.-jun. 2006. ilus, CD-ROM
Article in Portuguese | LILACS, BBO | ID: biblio-873585

ABSTRACT

Diversos procedimentos odontológicos favorecem a entrada de bactérias na corrente sanguínea, as denominadas bacteremias. Na maioria das vezes, as próprias defesas do organismo controlam esse processo. Entretanto, existem condições predisponentes, como por exemplo a presença de cardiopatias valvares, que podem levar a complicações sistêmicas, entre as quais a endocardite bacteriana. Para esses casos, faz-se necessária a profilaxia antibiótica previamente ao tratamento odontológico indutor de possível bacteremia. O presente artigo visa rever a literatura relativa às bacteremias de origem bucal, bem como o papel da profilaxia antibiótica frente às mesmas


Subject(s)
Antibiotic Prophylaxis , Bacteremia , Dental Instruments/microbiology , Mouth/microbiology , Dental Prophylaxis , Oral Health
10.
J. Health Sci. Inst ; 21(4): 375-380, out.-dez. 2003. ilus, tab
Article in Portuguese | LILACS | ID: lil-389327

ABSTRACT

Introdução - O objetivo deste trabalho foi comparar a resistência à compressão de restaurações parciais do tipo oniay confeccionadas nos materiais estéticos de uso indireto: cerâmica feidspática (Noritake; Noritake Co Ltd Japan) e duas resinas compostas de laboratório de segunda geração (Artglass, Kuizer Produtos Odontológicos Ltda Brasil e Targis, lvociar Vivadent Amherst NY). Métodos - A partir de um pré-molar humano superior preparado para receber uma restauração do tipo onlay, foram confeccionadas 30 réplicas na liga metálica NiCr. As réplicas foram divididas em três grupos de 10, a serem restauradas com os diferentes materiais: Grupo 1 (Noritake); Grupo 11 (Artgiass) e Grupo 111 (Targis). Após sua confecção de acordo com as recomendações dos fabricantes e controle de adaptação interna e marginal, as restaurações foram cimentadas às réplicas por meio de um cimento resinoso dual (Enforce, Dentspiy). As amostras foram submetidas ao teste de resistência à compressão numa máquina de testes universal (Kratos), e os resultados submetidos à análise estatística. Resultados - As médias de resistência à compressão (kgf) para os materiais estudados foram: Grupo 1: 259,75; Grupo li: 194,28 e Grupo Iii: 158,30. Conclusões - Os resultados do teste de Tukey demonstraram que não houve diferenças estatísticas entre os Grupos 1 (Noritake) e 11 (Artgiass) nem entre os Grupos 11 (Artglass) e 111 (Targis). Entretanto, as restaurações do Grupo 1 (Noritake) apresentaram resistência à com- pressão significativamente maior (p=0,01) que as restaurações do Grupo 111 (Targis).(au)


Subject(s)
Ceramics , Composite Resins , Dental Prosthesis , Dental Restoration Failure
SELECTION OF CITATIONS
SEARCH DETAIL